Indramat · IndraDrive MPx02
The IndraDrive MPx02 has detected the loss of one or more phases of the incoming three-phase AC mains supply. This condition prevents proper operation, leading to unbalanced currents and insufficient power, and can damage the drive and motor if not addressed promptly.
Click steps to track your progress.
Immediately power down the drive and visually inspect all fuses and circuit breakers in the incoming power supply circuit for the IndraDrive MPx02. Replace or reset as necessary.
Measure the voltage between all three phases (L1-L2, L2-L3, L3-L1) at the input terminals of the drive to confirm the presence of all phases and balanced voltages.
Check all power cable connections from the main supply to the drive, ensuring they are tight, correctly terminated, and free from corrosion.
Investigate the upstream power distribution system, including contactors and transformers, for any component failures.
If the problem persists and upstream power is confirmed healthy, the drive's input rectifier or phase sensing circuit may be faulty.