EL
ErrorLib
Brands
||
  1. Home
  2. Indramat
  3. IndraDrive MPx02
  4. E3107
About·Privacy·Terms

ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

E3107

Safety related reference missing

Indramat · IndraDrive MPx02

What does E3107 mean?

The IndraDrive MPx02's integrated safety technology is missing a required safety-related reference. This reference could be a specific position, velocity, or direction, which is crucial for safety functions like Safe Operating Stop or Safe Position monitoring. Without it, the safety system cannot guarantee safe operation.

Common Causes

  • The axis has not been safely homed or a safety-related reference point has not been established.
  • A critical encoder or sensor providing safety-related feedback is not active, has failed, or is incorrectly configured.
  • Incorrect parameterization of safety functions that require a validated reference position.
  • Loss of absolute position information for safety-related monitoring functions.
  • An invalid or unstable signal from a safety-related feedback device.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Ensure that the axis has undergone a successful safety-related homing procedure or that its absolute position reference is established and validated.

  2. 2

    Verify the functionality and wiring of any encoders or sensors designated for safety-related feedback to the IndraDrive MPx02.

  3. 3

    Check the safety configuration parameters to ensure that all required safety references are correctly defined and enabled.

  4. 4

    If using an absolute encoder for safety-related position monitoring, confirm its integrity and that its absolute position data is valid and retained.

  5. 5

    If the issue persists, review the machine's safety concept and the specific requirements for safety-related referencing, then contact Indramat safety service.

Browse all codes in this manual (56)
Verified technical data. Last updated: April 2026

Related Faults

E2010Position control with encoder 2 not possibleE2011PLC - Warning no. 1E2012PLC - Warning no. 2
Source: Indramat IndraDrive MPx02
Open Manual (Page 112)Search more codes in this manual