Indramat · IndraDrive MPx02
The IndraDrive MPx02's integrated safety technology has detected that the drive is enabled, but the motor is at a safety-related standstill. This condition is a warning indicating that the safety standstill function is active while the drive's power section is still enabled, which may not be the intended safe state or might indicate an issue with the safety circuit's command.
Click steps to track your progress.
Verify the status of all safety inputs to the IndraDrive MPx02 and the safety controller to confirm that safety functions (e.g., SOS) are correctly commanded.
Ensure that the drive enable signal from the master controller is being managed consistently with the active safety functions; if a safety standstill is required, the drive enable should typically be removed.
Review the configuration of the safety parameters in the IndraDrive MPx02, ensuring that the interaction between safety functions and drive enable is as intended.
Check the status of external safety devices (e.g., light curtains, safety gates, E-stop buttons) to ensure they are not inadvertently triggering a safety standstill while the drive is enabled.