Indramat · IndraDrive MPx02
The IndraDrive MPx02 has detected that the actual position of the axis has moved beyond the configured positive software travel limit (P-0-0045). This warning indicates that the axis has entered a restricted zone, and further movement in the positive direction may be prevented or cause a fault, protecting the machine from overtravel.
Click steps to track your progress.
Check the actual position of the axis and compare it to the configured positive software travel limit P-0-0045.
Move the axis manually or with a small negative jog command to bring it back within the permissible travel range.
Verify and adjust the parameter P-0-0045 (Position limit positive) to correctly match the physical positive travel limit of the machine, ensuring it provides adequate mechanical clearance.
Perform a homing procedure to re-establish the correct position reference if it may have been lost or corrupted.
Review the motion commands from the master controller to ensure target positions do not exceed the defined limits.