Indramat · IndraDrive MPx02
The torque or force command value issued to the IndraDrive MPx02 is being limited by a configured maximum value. This indicates that the requested torque/force from the master controller exceeds the drive's or application's set limit, and the drive is capping the output.
Click steps to track your progress.
Verify the commanded torque/force value from the master control system (PLC/CNC) and compare it against the drive's configured torque/force limit (e.g., S-0-0092).
If the application requires higher torque/force, and the motor/drive system can safely provide it, increase the torque/force limit parameter in the IndraDrive MPx02 configuration.
Assess if the mechanical load is higher than expected, requiring more torque than anticipated by the control program.
Review any scaling factors or units used for torque/force commands to ensure they are consistent between the master controller and the drive.
Check if any safety-related torque limitations are active and overriding the standard operating limits.