Target position out of numerical range
Indramat · CLM01.3-M Flying Cutoff Control
What does E264 mean?
In the drive-internal interpolation mode, the calculated target position cannot be represented within the internal position format limits of the Indramat DIAX04 SSE-03VRS controller. This can lead to incorrect axis positioning or movement failures.
Common Causes
- The commanded target position exceeds the numerically representable range of the drive.
- Position data for infinitely turning axes is not correctly illustrated in modulo format.
- The configured maximum travel range is too small for the intended motion profile.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Verify the commanded target position value from the control system and correct it if it exceeds the drive's internal limits.
- 2
For infinitely turning axes, ensure that position data is correctly set up and interpreted in modulo format within the application program and drive parameters.
- 3
Review and enlarge the maximum travel range parameter in the Indramat DIAX04 SSE-03VRS controller configuration, if the application requires larger travel.
- 4
Check the scaling and units of the position feedback and command values to ensure consistency.