E324
Option module error power supply unit
Indramat · CLM01.3-M Flying Cutoff Control
What does E324 mean?
A component connected to the Indramat HVE or HVR power supply unit within the DIAX04 SSE-03VRS system reports an internal malfunction. This indicates a problem with an auxiliary or expansion module.
Common Causes
- Internal fault within the option module connected to the power supply unit.
- Incorrect installation or connection of the option module.
- Power supply unit (HVE/HVR) itself may have a secondary fault affecting the option module.
- Mechanical damage or environmental factors affecting the option module.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Visually inspect the option module connected to the HVE or HVR power supply unit for any signs of damage or loose connections.
- 2
Verify that the option module is correctly installed and seated firmly in its slot.
- 3
Check the wiring and communication connections between the option module and the power supply unit.
- 4
If the fault persists, attempt to reseat the option module. If the problem continues, replace the option module.
Verified technical data. Last updated: March 2026
Related Faults
Source: Indramat CLM01.3-M Flying Cutoff Control