E350

Heatsink overtemperature warning power supply unit

Indramat · CLM01.3-M Flying Cutoff Control

What does E350 mean?

The heatsink temperature of the Indramat HVE or HVR power supply unit has reached its permissible limit, opening the temperature pre-warning contact. Power will be switched off after 30 seconds if the condition persists, indicating potential thermal overload of the DIAX04 SSE-03VRS.

Common Causes

  • The load on the power supply unit is too high, leading to excessive heat generation.
  • The ambient temperature within the control cabinet or operating environment is above the specified limit.
  • Cooling air ducts are blocked, restricting airflow to the heatsink.
  • The internal cooling blower of the HVE/HVR unit is defective or obstructed.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Reduce the operational load on the power supply unit to decrease heat generation.

  2. 2

    Measure and reduce the control cabinet's internal temperature to within specified operating limits.

  3. 3

    Inspect and clear any obstructions in the cooling air ducts or ventilation openings of the Indramat DIAX04 SSE-03VRS power supply unit.

  4. 4

    Verify the operation of the internal blower; if it's defective, the power supply unit requires replacement.

Browse all codes in this manual (31)
Verified technical data. Last updated: March 2026