E408

Invalid addressing of MDT-data container A

Indramat · CLM01.3-M Flying Cutoff Control

What does E408 mean?

This warning from the Indramat DIAX04 SSE-03VRS indicates an error during the index check in the multiplex channel. During cyclical data exchange, the index used to access the S-0-0370 (Configuration list for MDT data container) points to a non-initialized field in the list, preventing proper data access.

Common Causes

  • The index for accessing the S-0-0370 list is incorrectly calculated or provided by the control system.
  • The S-0-0370, Configuration list for MDT data container has not been properly initialized or configured.
  • Corruption of data within the multiplex channel or the S-0-0370 list.
  • Timing issues in cyclical data exchange leading to invalid index reads.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the programming of the control system that generates the index for accessing the S-0-0370 list, ensuring it points to valid, initialized fields.

  2. 2

    Check the configuration and initialization of the S-0-0370, Configuration list for MDT data container parameter in the Indramat DIAX04 SSE-03VRS, ensuring all necessary fields are properly defined.

  3. 3

    Re-initialize the drive configuration or relevant parameters to ensure the MDT data container list is correctly set up.

  4. 4

    Review the cyclical data exchange timing and synchronization between the controller and drive to rule out timing-related issues.

Browse all codes in this manual (31)