Phase switching without ready signal
Indramat · CLM01.3-M Flying Cutoff Control
What does F406 mean?
The SERCOS master attempted a phase switch without waiting for the drive controller’s ready signal, indicating an error in the SERCOS master module of the control system.
Common Causes
- Error in the SERCOS master module of the control system.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Review the SERCOS master controller's diagnostic messages and event logs for further details regarding the premature phase switch attempt.
- 2
Verify the SERCOS communication parameters and timing settings in the master controller to ensure they align with the requirements of the Indramat DIAX04 SSE-03VRS drive controllers.
- 3
Check the firmware version of the SERCOS master module for any known issues or required updates.
- 4
Monitor the ready signal status from the Indramat DIAX04 SSE-03VRS drive controllers to confirm they are indeed reporting their ready state correctly.
- 5
If the problem persists and appears to originate from the master controller's logic or hardware, consult the control system manufacturer for advanced diagnostics or potential module replacement.