F7043

Error of output stage interlock

Indramat · Indradrive

What does F7043 mean?

This safety fault indicates a problem with the interlock circuit that controls the output stage (power section) of the drive. The interlock is a critical safety mechanism that prevents the drive from applying power to the motor unless all safety conditions are met, and an error means it's not functioning correctly.

Common Causes

  • Faulty internal hardware (e.g., relays, contactors) of the output stage interlock.
  • Short circuit or open circuit in the interlock control path.
  • Incorrect external wiring to safety inputs, preventing the interlock from being correctly released.
  • Internal diagnostic failure of the safety module monitoring the interlock.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Cycle power to the IndraDrive.

  2. 2

    Verify all external safety input signals (e.g., STO, enable) are present and correctly wired, ensuring they are not preventing the interlock from clearing.

  3. 3

    Review relevant safety parameters in the IndraDrive that control the output stage interlock.

  4. 4

    Check the drive's internal diagnostics (if available) for specific error codes related to the output stage or safety relays.

  5. 5

    If the fault persists after external checks, the drive's safety module or power section hardware likely requires service or replacement.