Indramat · ServoDyn D Servo Drive
This error occurs when an invalid value is stored in a CLM01.3-M parameter, exceeding its defined minimum or maximum limits. The invalid data is typically indicated by an asterisk (*) on the display, and the error message appears on the first line.
Click steps to track your progress.
Identify the specific parameter indicated on the CLM01.3-M display that is showing an invalid input (e.g., with an asterisk).
Switch the CLM01.3-M to Parameter mode, navigate to the affected parameter, and press the CL (Clear) key to remove the invalid data.
Consult Chapter 4 of the manual to verify the correct minimum, maximum, and format requirements for the identified parameter.
Re-enter the correct parameter value, ensuring it adheres to all specified limits and data types.
If the error re-occurs, verify that the entry keypad or any external input device is functioning correctly and not sending corrupted data.