Indramat · ServoDyn D Servo Drive
This error occurs when Axis 2 is commanded to a position but the Axis 2 servo system exhibits excessive position lag, meaning it is not following the commanded trajectory accurately. This often points to issues with the drive's power, feedback, or tuning.
Click steps to track your progress.
Verify that the Axis 2 servo amplifier is powered ON, free of faults, and receiving the enable signal at CLM01.3-M connector X4, pin 14.
Confirm Parameter P41 (Encoder Data A2) matches the encoder and Parameter P43 (Drive Sensit. A2) RPM/Volt matches the amplifier's input (E1/E2).
Reduce Parameter P44 (Acceleration Rate A2) to a value the Axis 2 motor can physically achieve.
Check all connections of the Axis 2 encoder cable to CLM01.3-M connector X2 and to the motor, ensuring proper wiring and shielding.
Inspect the Axis 2 mechanical system for any binding, excessive load, or friction that would hinder smooth movement.
If issues persist after these checks, consider testing or replacing the Axis 2 encoder or servo amplifier.