Indramat · ServoDyn D Servo Drive
This error occurs if the absolute encoder for Axis 1 is not properly connected, or if data transmission between the encoder and the CLM01.3-M is interrupted or corrupted. This prevents the system from obtaining an absolute position reference for Axis 1.
Click steps to track your progress.
Verify that Parameter P01 (Encoder Data A1) for Axis 1 correctly matches the specifications of the installed absolute encoder (e.g., number of bits, revolutions).
Inspect the physical connections of the absolute encoder cable to both the Axis 1 motor and the CLM01.3-M for secure and correct wiring.
Check the absolute encoder cable for any signs of damage, fraying, or loose shielding.
Test the absolute encoder for proper operation, potentially by checking its output signals if diagnostic tools are available.
If the error persists after thorough checks, consider replacing the absolute encoder or its cable.