Indramat · ServoDyn D Servo Drive
This error occurs if Axis 2 travels beyond the maximum number of turns (revolutions) supported by its absolute encoder. This indicates an overtravel condition relative to the encoder's multi-turn counting capability, preventing accurate position tracking.
Click steps to track your progress.
Verify that Parameter P41 (Encoder Data A2) for Axis 2 accurately reflects the total number of revolutions of the absolute encoder.
Adjust the programmed travel limits (e.g., Parameters 51 and 52 for Axis 2) to ensure they are within the absolute encoder's operational range.
Inspect the mechanical system of Axis 2 for any overtravel, binding, or obstructions that would cause it to exceed the encoder's limits.
If a discrepancy exists, compare the value stored in Parameter P41 with the information on the absolute encoder's nameplate.
Review the application's motion profile to ensure that commanded movements for Axis 2 remain within the safe operating range of the absolute encoder.