35

Max Travel Lmt 2

Indramat · ServoDyn D Servo Drive

What does 35 mean?

This error occurs in Automatic mode for Axis 2 if the commanded position is greater than the value configured in Parameter 52 (Maximum Travel Limit A2). The system detects an attempt to move Axis 2 beyond its defined maximum operational boundary.

Common Causes

  • The programmed command attempts to move Axis 2 above its Maximum Travel Limit set in Parameter 52.
  • Parameter 52 (Maximum Travel Limit A2) is set incorrectly or too low for the actual mechanical limits of Axis 2.
  • Overshoot of Axis 2 during acceleration or homing, causing it to briefly exceed the maximum limit.
  • Incorrect position gain (Parameter 45) or tuning, leading to poor positioning accuracy for Axis 2.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    The Axis 2 commanded position has exceeded the Axis 2 maximum travel limit.

  2. 2

    Ensure that Parameter 52 (Maximum Travel Limit A2) is correctly set to reflect the actual maximum mechanical travel limit for Axis 2.

  3. 3

    Adjust the user program to ensure that commanded positions for Axis 2 do not exceed the value specified in Parameter 52.

  4. 4

    Optimize the position gain (Parameter 45) for Axis 2 to improve acceleration and stopping accuracy if overshoot is observed.

  5. 5

    Inspect the mechanical system for any binding or obstructions that could restrict movement or cause overtravel for Axis 2.

Browse all codes in this manual (51)