Indramat · ServoDyn D Servo Drive
This error occurs if the user program attempts to execute an absolute position command for Axis 2, but Axis 2 has not yet been homed. Homing is essential to establish a precise absolute position reference.
Click steps to track your progress.
Verify that Axis 2 parameters are correctly set for homing. Axis 2 can be homed in Manual or Automatic mode (refer to Chapter 4).
Review the CLM01.3-M user program to ensure that absolute position commands for Axis 2 are only issued after Axis 2 has been homed.
Perform the homing procedure for Axis 2 in either Manual or Automatic mode to establish a home reference.
Inspect the home limit switch for Axis 2, including its wiring and mechanical actuation, to ensure it is functioning correctly.
Check for any mechanical obstructions or binding that might prevent Axis 2 from reaching its home position during the homing cycle.