The "Synchronization Difference A2" error occurs when the position difference between Axis 1 and Axis 2 motors exceeds the value configured in Parameter 40 (Synchr. Diff. A2). This indicates a loss of coordinated motion between the synchronized axes.
Click steps to track your progress.
Verify that the parameter entries for Axis 1 and Axis 2, particularly feed constants and encoder data, are identical.
Inspect both Axis 1 and Axis 2 for any signs of skewing or mechanical binding that could hinder synchronized movement.
Increase the value of Parameter 40 (Synchr. Diff. A2) if the application tolerates a larger synchronization difference.
Review and optimize the position control loop tuning for both Axis 1 (Parameter 05) and Axis 2 (Parameter 45).
Check the encoder feedback signals from both axes for accuracy and consistency.