Indramat · ServoDyn D Servo Drive
This serial communication error indicates that the parameter number transmitted to the CLM01.3-M is invalid. The parameter number must be provided in a two-digit format and fall within the range of 00 to 99.
Click steps to track your progress.
Verify that the parameter number being transmitted is a two-digit number between 00 and 99. Refer to Chapter 7 (Serial Interface) for the correct parameter format.
Correct the parameter number in the transmitted serial command to adhere to the specified format and range.
Check the serial communication link for noise, interference, or incorrect cabling that could corrupt data.
Re-transmit the parameter command after verifying the parameter number and overall command format.
Ensure the sending device's software generates parameter numbers correctly according to the CLM01.3-M specifications.