Kone · Elevator Control
A logic failure of type #3 has occurred in the motor controller (codes 1017, 2017, 3017). This indicates an internal control logic error, preventing correct operation. The specific lift reaction is controller dependent.
Click steps to track your progress.
Measure all supply voltages to the motor controller and associated power supply units against specified nominal values.
Inspect all external wiring connections to the motor controller, including power, motor, feedback, and communication cables, for looseness, damage, or corrosion.
Verify that all operational parameters and configured software/firmware versions in the motor controller match the approved documentation.
Perform a controlled power cycle of the motor controller to clear any potential transient logic errors.
Check the motor controller's internal diagnostic logs for any preceding or related fault codes that could indicate a root cause.