Kone · Elevator Control
A logic failure of type #1 has occurred in the motor controller (codes 1019, 2019, 3019). This indicates an internal control logic error, preventing correct operation. The specific lift reaction is controller dependent.
Click steps to track your progress.
Verify main AC/DC supply voltage to the motor controller input terminals against nominal specifications and stability.
Check and compare current operational parameters and configuration settings of the motor controller against the documented system backup or factory defaults.
Inspect and verify the operational status of critical inputs such as encoder feedback, limit switches, and safety circuit signals via the controller's diagnostic interface.
Perform a controlled power cycle of the motor controller after safely stopping the elevator, observing for recurrence of the error.