PCU: n3, ECU: 3XXX code

Pump Motor Controller Fault

Kone · Elevator Control

What does PCU: n3, ECU: 3XXX code mean?

A fault has occurred in the motor controller for the pump (PCU: n3, ECU: 3XXX code series). The specific reaction depends on the controller's configuration and the nature of the fault.

Common Causes

  • Internal failure within the Pump Motor Controller module.
  • Communication error with the Pump Motor Controller.
  • Faulty pump motor or wiring connected to the pump motor controller.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the incoming three-phase supply voltage and control power voltage at the motor controller's input terminals against the nominal specification.

  2. 2

    Inspect all motor power cables and control wiring between the motor controller and the pump motor for damage, corrosion, or loose terminations.

  3. 3

    Check the motor controller's diagnostic display for specific sub-fault codes or warning messages, and verify critical motor parameters (e.g., motor type, current limits, acceleration/deceleration times) against system documentation.

  4. 4

    Measure the insulation resistance of the pump motor windings to ground and between phases using a megohmmeter to detect potential motor winding faults.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026