Lenze · 9300 Series
An error has occurred in the parameter set, possibly due to an operating system software update. The Lenze default settings (C0003 = 1) are automatically loaded as a result of this fault.
Click steps to track your progress.
Cycle power to the drive and check if the fault clears and the default parameters (C0003 = 1) are active.
Verify the current firmware version (C0004) and ensure any loaded parameter set is compatible with it.
Reload the last known good parameter set from a backup file using the drive's configuration software (e.g., "Lenze Engineer").
Manually re-enter critical application parameters (e.g., motor data, speed limits) and save them to non-volatile memory (e.g., by setting C0003 = 2).
If the fault recurs with new parameters, inspect the drive's internal memory health via diagnostic parameters if available (refer to manual for specific memory status indicators).