An error occurred during motor data identification, indicating the connected motor may be too small for the drive. This can also be caused by an externally inhibited controller during the identification process, preventing proper measurement.
Click steps to track your progress.
Compare the motor's rated power and current (from its nameplate) with the drive's specifications to confirm appropriate sizing.
Verify the entered motor parameters (P1-01 (motor rated power), P1-02 (motor rated current), P1-03 (motor rated frequency)) are accurate.
Ensure all drive enable inputs (e.g., terminal X3/1, if used) are continuously active (HIGH) during the entire identification process.
Attempt identification with an alternative motor of known compatible size, if available, to rule out a drive-specific issue.
If the motor is correctly sized, try adjusting any gain parameters related to current measurement (if available, e.g., P5-xx) or consult the manual for specific ID tuning.