Lenze · 9300 Series
A resolver error has occurred at terminal X7, typically indicating an interrupted resolver cable. This prevents accurate position feedback.
Click steps to track your progress.
1. Power down and lockout the drive. Disconnect the resolver cable from terminal X7 on the drive and at the resolver end.
2. Using a multimeter, check continuity of each individual wire within the resolver cable from end to end.
3. Measure the resistance of the resolver windings at the resolver connector (e.g., between reference and sine, reference and cosine). Refer to the resolver datasheet for expected values.
4. Inspect terminal X7 on the drive and the resolver connector for bent pins, corrosion, or loose connections.
5. Ensure the resolver cable shield is properly connected to the drive's designated ground terminal and the motor frame.