Lenze · 9300 Series
The positive position limit (C1223) was exceeded, potentially due to incorrect position targets or issues with the 'set function position value'. This can cause the drive to overtravel its intended positive extreme.
Click steps to track your progress.
1. Verify the positive position limit value (Parameter C1223) in the drive's configuration and compare it to the actual mechanical travel range of the system.
2. Review the motion program for any commands that set or offset the current position (e.g., 'set function position value') and ensure they are correct.
3. Re-execute the homing procedure to establish a precise and repeatable absolute reference point for the drive.
4. Monitor the actual position (P5-04) and commanded position (P5-05) in real-time as the drive approaches the positive limit.
5. Temporarily adjust the positive position limit (C1223) to a larger value, then manually jog the system to the desired positive mechanical stop and set C1223 just below it.