Lenze · 9300 Series
The sensor for detecting the internal temperature of the controller is indicating undefined values. This prevents accurate monitoring of the internal component temperature, risking damage from overheating.
Click steps to track your progress.
Power cycle the drive (disconnect mains, wait 5 minutes) to reset the internal monitoring circuits.
Ensure the ambient temperature around the drive is within the specified operating limits (e.g., 0-50°C) as per the datasheet.
Inspect the control board for any visible damage or signs of overheating, particularly around the temperature sensor component (often a small SMD thermistor).
Check all internal ribbon cables and connectors on the control board for proper seating and connection.
If applicable, use diagnostic software to view the raw internal temperature sensor value; if it's constantly at an extreme (e.g., -40°C or +150°C), the sensor is likely faulty.