The phase controller limit has been reached, meaning the drive cannot follow the digital frequency due to hitting its Imax limit. This indicates the drive is being commanded beyond its current capability, potentially causing instability.
Click steps to track your progress.
Monitor the actual motor current (e.g., C0004) and compare it against the drive's instantaneous current limit (P1-54, P1-55); if consistently hitting the limit, adjust P1-54 upwards within motor ratings.
Verify mechanical system integrity for any increased friction, binding, or sudden load changes that could demand excessive torque.
Adjust the current controller gains (C0207 for P gain, C0208 for I gain) if the current response is sluggish, following manufacturer guidelines.
Reduce the acceleration ramp time (e.g., C0256) or maximum speed command (e.g., C0258) to ease the dynamic demands on the motor.
Check the motor's temperature (e.g., via C0005 if a sensor is present) and for any unusual noises or vibrations that could indicate a motor issue.