Lenze · 9300 Series
The heatsink temperature has exceeded the specific threshold value set in parameter C0122. This is an advance warning for heatsink overheating, which can be caused by high ambient temperatures (Tu > +40°C or +50°C), a dirty heatsink, or an incorrect mounting position. This monitoring can be switched off via C0582.
Click steps to track your progress.
Measure the control cabinet ambient temperature (e.g., with a thermometer) and compare it to the drive's specification.
Clean the drive's heatsink fins with compressed air to ensure maximum surface area for heat dissipation.
Monitor the drive's internal cooling fan operation, checking for consistent rotation and lack of obstruction.
Review parameter C0122 (Heatsink temperature warning threshold) and consider raising it slightly if current operating conditions are normal.
Ensure adequate ventilation in the control cabinet, checking fan filters and ensuring sufficient clearance around the drive for airflow.