Lenze · 9300 Series
An error has been detected with the thermal sensor connected to the motor inputs X7 or X8. This indicates a malfunction of the sensor itself or an issue with its wiring, preventing accurate motor temperature monitoring. This monitoring is controlled by parameter C0594.
Click steps to track your progress.
Disconnect the thermal sensor wires from X7 or X8 and measure the sensor's resistance directly at the motor leads with an ohmmeter (compare to sensor datasheet).
Inspect the entire length of the thermal sensor cable from the motor to the drive's terminals X7/X8 for breaks, chafing, or corrosion.
Verify the parameter setting for the motor thermal sensor type (e.g., P3-10 for PTC or KTY) matches the installed sensor.
Check for proper grounding and shielding of the thermal sensor cable to minimize electrical noise pick-up.
If the sensor resistance is outside normal limits or wiring is confirmed good, consider replacing the motor's integrated thermal sensor.