Lenze · i550 Protec Drive
This fault indicates that the inverter's device utilization (I²t) is excessively high, typically caused by frequent and/or prolonged acceleration processes. This condition is configurable and causes the inverter to disable immediately, requiring a 3-second blocking time before a reset.
Click steps to track your progress.
Review application acceleration and deceleration ramp times (e.g., P1-10, P1-11); increase ramp times to reduce peak currents if the application allows.
Reduce the mechanical load on the motor if it is consistently high, or consider upsizing the inverter if the load cannot be reduced.
Inspect inverter cooling fans for proper operation and clean the heatsink fins to ensure optimal heat dissipation.
Verify the inverter's I²t thermal model parameters (e.g., P0-21, P0-22) are correctly set according to the application and environmental conditions.
Measure the ambient temperature inside the electrical cabinet and ensure it is within the inverter's specified operating range.
Check motor parameters (P0-11 for rated power, P0-12 for rated current, P0-13 for rated speed) for accuracy as they influence the inverter's internal thermal model.