Lenze · i550 Protec Drive
This fault occurs when the maximum current of the axis (display in 0x2DDF:002) has been reached too frequently in succession. This indicates the system is hitting current limits repeatedly.
Click steps to track your progress.
Monitor the actual current (0x6078) and torque reference via diagnostic tools during operation to identify peak load events.
Inspect the mechanical system for binding, misalignment, or obstructions preventing free movement of the axis.
Increase the acceleration and deceleration ramp times (e.g., P2-10, P2-11) in small increments and retest.
Verify the motor sizing against the application's peak and continuous torque requirements. Consider upgrading the motor or drive if consistently undersized.
Check the motor brake operation and wiring (e.g., terminals X1:1, X1:2) for proper release and engagement timing.
Lubricate moving parts and inspect bearings for excessive wear, replacing as necessary.