0x2387

Clamp responded too often

Lenze · i550 Protec Drive

What does 0x2387 mean?

This fault occurs when the maximum current of the axis (display in 0x2DDF:002) has been reached too frequently in succession. This indicates the system is hitting current limits repeatedly.

Common Causes

  • Repeated mechanical jamming or obstruction in the driven axis, causing high current spikes.
  • Insufficient motor sizing for the application's peak torque demands, leading to frequent current limit hits.
  • Acceleration/deceleration ramps (e.g., P2-10, P2-11) configured too aggressively for the motor's capabilities and load inertia.
  • Motor brake (if present) engaging or disengaging incorrectly, causing transient overcurrents during motion.
  • Damaged or worn mechanical components (e.g., bearings, gears) increasing friction and required motor torque.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Monitor the actual current (0x6078) and torque reference via diagnostic tools during operation to identify peak load events.

  2. 2

    Inspect the mechanical system for binding, misalignment, or obstructions preventing free movement of the axis.

  3. 3

    Increase the acceleration and deceleration ramp times (e.g., P2-10, P2-11) in small increments and retest.

  4. 4

    Verify the motor sizing against the application's peak and continuous torque requirements. Consider upgrading the motor or drive if consistently undersized.

  5. 5

    Check the motor brake operation and wiring (e.g., terminals X1:1, X1:2) for proper release and engagement timing.

  6. 6

    Lubricate moving parts and inspect bearings for excessive wear, replacing as necessary.

Browse all codes in this manual (52)