Lenze · i550 Protec Drive
This fault indicates that the parameter settings in the memory module originate from an inverter with different hardware, for example, a different power rating. The data is loaded into RAM without modification, and while compatible, requires user acceptance.
Click steps to track your progress.
Confirm that the EPM module installed is the correct one for the specific inverter model and power rating in use.
Backup existing parameters to a PC tool if possible, then perform a factory reset (e.g., P99.00 = 1) and re-enter all parameters manually.
Replace the EPM module with a new, blank one or one previously saved from the current inverter.
If commissioning a new setup, ensure the EPM is initialized for the installed inverter, then save parameters from the inverter to the EPM.
Check for any available firmware updates for the inverter that might address compatibility issues with EPM modules.