The monitoring of the input signal configured for the HTL input has been triggered. This indicates a problem with the High-Threshold Logic input signal, potentially an unexpected pulse count or signal level.
Click steps to track your progress.
Measure the 24VDC supply voltage at the HTL encoder's power terminals (e.g., X5.1) to ensure it is within specified limits.
Using an oscilloscope, monitor the HTL A, B, and Z signals at the drive's input terminals (e.g., X5.2, X5.3, X5.4) for proper waveform and absence of noise.
Inspect the HTL encoder cable for physical damage, proper shielding, and secure connections at both the encoder and drive ends.
Verify the drive's parameters related to HTL input monitoring (e.g., minimum frequency threshold, number of pulses per revolution).
Swap the HTL encoder with a known good unit (if available) to differentiate between encoder failure and drive input issues.