30354

EPM data: new firmware type detected

Lenze · i550 Protec Drive

What does 30354 mean?

The parameter settings stored in the memory module do not precisely match the current inverter hardware configuration, even though they were loaded into RAM as compatible. User acceptance of these settings is required.

Common Causes

  • The EPM originated from an inverter with minor hardware differences (e.g., different option card, slight revision) but shares a compatible core firmware.
  • The inverter's firmware was recently updated, resulting in minor parameter re-mapping, new default values, or additional parameters that differ from the EPM's stored data.
  • An EPM containing parameters from a similar, but not identical, inverter model within the same product family was inserted.
  • A parameter migration or conversion process was performed on the EPM data, but some minor inconsistencies or new settings requiring user confirmation were introduced.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    1. Carefully read and confirm the acceptance prompt displayed on the drive's HMI or programming software, acknowledging the detected parameter differences.

  2. 2

    2. After accepting the EPM data, thoroughly review critical drive parameters (e.g., motor data P2-10 to P2-16, ramp times P1-05/P1-06, control mode P1-01) for accuracy.

  3. 3

    3. Perform a controlled, low-speed, and low-load test run of the motor and application while closely monitoring drive output current (P3-01) and motor speed (P3-02).

  4. 4

    4. Use the drive's software tool to compare the loaded parameters against a known good parameter set for the exact inverter hardware configuration to identify discrepancies.

  5. 5

    5. If unexpected behavior occurs, back up the EPM data, then perform a factory reset (e.g., P99.02=1) and reload parameters specific to the current inverter hardware.

Browse all codes in this manual (52)
Verified technical data. Last updated: April 2026

Related Faults

0x2250CiA: Continuous over current (internal)0x2320Short circuit or earth leakage at the motor end0x2340Short circuit at the motor end
Source: Lenze i550 Protec Drive
Open Manual (Page 623)Search more codes in this manual