E.CDO

Abnormal Output Current Detection

Mitsubishi Electric · FR-A800 Variable Speed Drive (Separated Converter)

What does E.CDO mean?

This fault indicates that the FR-A800 inverter has detected an abnormal current in its output circuit. This can signify a problem with the motor, motor wiring, or the inverter's output stage.

Common Causes

  • Short circuit or ground fault in the motor power cables or within the motor windings.
  • Overload condition on the motor, causing currents to exceed rated values.
  • Damage or malfunction of the inverter's output current sensors or power semiconductors.
  • Incorrect motor parameters (e.g., Pr.7, Pr.9) or tuning settings (e.g., auto tuning) leading to unstable current control.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Immediately inspect the motor power cables (U, V, W) for any signs of damage, insulation breakdown, or improper connections.

  2. 2

    Perform an insulation resistance test on the motor windings and power cables to ground and phase-to-phase using a megohmmeter (expect >1 MΩ).

  3. 3

    Check for any mechanical binding, blockage, or excessive load on the motor that could cause overcurrents.

  4. 4

    Verify that the motor parameters (Pr.7, Pr.9, etc.) stored in the FR-A800 match the motor nameplate data.

  5. 5

    If possible, disconnect the motor and run the inverter with no load (ensure no output phase loss is triggered) to determine if the fault is internal to the inverter or external.

Browse all codes in this manual (46)