E.5

Generic Panel Fault 5 (CPU Fault)

Mitsubishi Electric · FR-D700 Inverter

What does E.5 mean?

This is a panel display code (specifically for FR-PU04/FR-PU07) that indicates a CPU fault (E.CPU) is active. The underlying issue is a communication fault of the built-in CPU, leading to inverter output stoppage. It signals a critical internal processing error that prevents normal operation.

Common Causes

  • Internal communication bus failure or data corruption within the inverter's main CPU unit.
  • Hardware malfunction of the CPU board itself due to component degradation or manufacturing defect.
  • Electromagnetic interference (EMI) or transient voltage spikes affecting the delicate internal control circuitry.
  • Power supply ripple or instability within the inverter's control section, preventing stable CPU operation.
  • Firmware corruption or an unrecoverable software error within the inverter's operating system.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Power cycle the inverter completely (remove main power supply R/L1, S/L2, T/L3 for 5 minutes) to clear any transient CPU state.

  2. 2

    Check input power quality at the inverter's L1, L2, L3 terminals for voltage stability (e.g., 400V +/-10%) and absence of sags/swells using a multimeter.

  3. 3

    Disconnect all external control wiring (terminal STF, STR, SD, etc.) and run the inverter in basic local control (via PU/Panel) to rule out external interference.

  4. 4

    Perform a parameter initialization (clear all parameters to factory defaults, e.g., Pr. 160 = 1 or Pr. 77 = 1) and re-enter essential settings.

  5. 5

    Visually inspect the inverter's control board for any signs of physical damage, burn marks, or bulging capacitors.