E36

Abnormally High Discharge Temperature / Insufficient Refrigerant / THOD Defective

Mitsubishi Electric · FR-D700 Inverter

What does E36 mean?

The compressor discharge temperature is abnormally high. This can be caused by insufficient refrigerant, a defective compressor discharge temperature sensor (THOD), or other system issues leading to compressor overheating and potential damage.

Common Causes

  • Compressor discharge temperature sensor (ThOD, e.g., P18) is defective.
  • System is critically low on refrigerant.
  • Excessive heat load on the compressor.
  • Faulty compressor cooling mechanism.
  • High discharge pressure reducing cooling efficiency.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the refrigerant charge in the system using a manifold gauge set.

  2. 2

    Measure the resistance of the compressor discharge temperature sensor (THOD) and compare to specification.

  3. 3

    Inspect the condenser coil for obstructions or dirt, ensuring adequate airflow across the coil.

  4. 4

    Check for proper operation of the outdoor fan motor and fan blade integrity.