This fault occurs when the actual position deviation in the FR-A800/A800 Plus Series drive exceeds the permitted threshold, typically in applications requiring precise position control with a feedback device. This indicates a failure to maintain the commanded position.
Click steps to track your progress.
Verify all position control parameters, including position loop gains and following error limits, are correctly tuned for the mechanical system and application.
Inspect the mechanical system for any binding, excessive friction, backlash, or disconnection between the motor and the load.
Check the position feedback device (e.g., encoder) for proper operation, secure mounting, and signal integrity. Verify wiring to the FR-A800/A800 Plus Series drive.
Monitor the commanded position and actual position feedback through the drive's display or FR Configurator2 to assess the deviation.
Reduce the commanded acceleration/deceleration rates or velocity limits from the external controller to determine if the fault can be avoided.