The system is unable to identify the drive's size. The bridge type, ampere rating, and current feedback scaling are determined by a sense resistor on the Cube ID PCB, which plugs into the A2 Armature Interface PCB. This fault occurs if the computer cannot identify this physical hardware. A DSD power down is required.
Click steps to track your progress.
Ensure that connector J14 on the Main Control PCB is properly seated.
Verify that the correct Cube ID PCB is installed and present on the A2 Armature Interface PCB.
Check that the correct PCU software version is installed in U13 & U14.
If issues persist after checking connections and software, replace the Armature Interface PCB (A2) or the Drive Control PCB.
Perform a DSD power down.