EL
ErrorLib
Brands
||
  1. Home
  2. Otis
  3. DSD 412 DC Elevator Drive
  4. 923
About·Privacy·Terms

ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

923

LOAD CURRENT SETTING FAULT

Otis · DSD 412 DC Elevator Drive

What does 923 mean?

This fault is declared if the number entered for Rated Armature Current (parameter #3) is outside the acceptable range of 0.125 to 2.0 times the bridge current rating, which is determined by the bridge sense resistor on the Cube ID PCB located on the Armature Interface PCB. A DSD power down is required.

Common Causes

  • The value for parameter #3 (Rated Armature Current) is set outside the acceptable range (0.125 to 2.0 times the drive's bridge current rating).

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Enter a value for parameter #3 (Rated Armature Current) that is within 0.125 to 2.0 times the drive's bridge current rating.

  2. 2

    Perform a DSD power down after adjusting the parameter.

Browse all codes in this manual (48)
Verified technical data. Last updated: April 2026

Related Faults

117/118SERIAL COMMUNICATION FAULT400MOTOR OVERLOAD FAULT401EXCESSIVE FIELD CURRENT
Source: Otis DSD 412 DC Elevator Drive
Open Manual (Page 86)Search more codes in this manual