404

OPEN ARMATURE CIRCUIT

Otis · DSD 412 Elevator System

What does 404 mean?

This fault occurs when a large current error is detected in the armature circuit and persists for half a second. This indicates a break in the armature current path.

Common Causes

  • Open DC link fuse F4.
  • Break or poor connection in the motor armature circuit wiring.
  • Faulty or open power poles within the DC loop contactor.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the DC link fuse F4 for continuity and replace if blown.

  2. 2

    Inspect all connections and wiring in the motor armature circuit for any open circuits.

  3. 3

    Examine the power poles in the DC loop contactor for proper contact and integrity.

Browse all codes in this manual (57)