901

PCU IST FAULT

Otis · DSD 412 Elevator System

What does 901 mean?

Current flow in excess of 300% of the rated armature current has been detected.

Common Causes

  • Ground fault or intermittent connection in the motor armature circuit.
  • Faulty current measuring module.
  • Poor current regulator tuning.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the motor armature circuit for ground faults or intermittent connections.

  2. 2

    Inspect the current measuring module for faults.

  3. 3

    Adjust current regulator tuning parameters.