912

OPEN SCR FAULT

Otis · DSD 412 Elevator System

What does 912 mean?

One of the SCRs does not conduct current as expected. This condition is checked only upon request through the PCU #998 Diagnostics CDU function. The optional handheld PCDU can identify which specific SCR pair is faulty. This fault requires a DSD Power Down.

Common Causes

  • Non-conducting SCR.
  • Faulty SCR gating leads.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Use the PCU #998 Diagnostics CDU function to identify the non-conducting SCR pair.

  2. 2

    Check for faulty SCR gating leads.

  3. 3

    Replace the faulty SCR.