EL
ErrorLib
Brands
||
  1. Home
  2. Otis
  3. DSD 412 Elevator System
  4. 924
About·Privacy·Terms

ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

924

FIELD CURRENT SETTING FAULT

Otis · DSD 412 Elevator System

What does 924 mean?

This fault is declared if a number entered for Rated Field Current #50 is outside the acceptable range of the Field Interface board, A3, current rating. This rating is determined by the field sense resistor selected by SW1 on the Field Interface PCB. This fault requires a DSD power down.

Common Causes

  • Rated Field Current parameter #50 set outside the acceptable range of the Field Interface board, A3, current rating.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Enter a valid number for Rated Field Current, #50, within the acceptable range determined by the Field Interface board, A3, current rating and SW1 selection.

Browse all codes in this manual (57)
Verified technical data. Last updated: April 2026

Related Faults

117/118SERIAL COMMUNICATION FAULT400MOTOR OVERLOAD FAULT401EXCESSIVE FIELD CURRENT
Source: Otis DSD 412 Elevator System
Open Manual (Page 89)Search more codes in this manual