Schneider Electric · XW Pro NA Operation Guide
This Manual Fault occurs when the external AC sync port connection or cable is faulty, or something is improperly plugged into the AC sync port in a single-inverter system. This prevents proper synchronization.
Click steps to track your progress.
1. Inspect the external AC sync cable for physical damage, proper seating in the 'AC Sync' port, and verify continuity of all conductors using a multimeter.
2. Measure the voltage present on the 'AC Sync' port terminals (e.g., pins 1 and 2) using an oscilloscope to verify signal integrity (e.g., 5V, 50/60Hz square wave).
3. Verify that the external sync source is operational and providing the correct synchronization signal output, matching the inverter's expected specifications.
4. Temporarily disable external synchronization (set Parameter P2-10 to 'Internal Sync') to confirm the inverter operates normally without the external source.
5. Check terminal connections for the AC sync signal on both the inverter and the external sync source for tightness and proper polarity.