97

Copy error

SEW Eurodrive · MCBSM

What does 97 mean?

Immediate switch-off with inhibit. This fault occurs if the parameter module is removed or the unit is switched off/on during a copying process. This leads to incomplete or corrupted data transfer, making the system configuration unreliable.

Common Causes

  • Error during data transfer or copying operation.
  • Source and destination data integrity mismatch.
  • Interruption of data stream during copy process.
  • Insufficient memory buffer for copy operation.
  • Faulty communication link during data transfer.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Prior to confirming the error, load factory settings or a complete data set from the parameter module to restore a valid configuration.

  2. 2

    Ensure the parameter module remains securely connected and power is stable during any copying process.