EL
ErrorLib
Brands
||
  1. Home
  2. SEW Eurodrive
  3. MOVITRAC 07B System
  4. F47
About·Privacy·Terms

ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

F47

System bus 1 timeout

SEW Eurodrive · MOVITRAC 07B System

What does F47 mean?

A stop without inhibit occurs due to a communication fault via system bus 1. This can be related to the bus connection, parameter P808, the voltage supply of the FSE24B module, or EtherCAT communication issues with the connected FSE24B.

Common Causes

  • Fault during communication via system bus
  • Incorrect setting of parameter P808
  • Voltage supply issue of FSE24B module
  • EtherCAT communication problem with connected FSE24B

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check system bus connection for integrity, including cables and connectors

  2. 2

    Check the value of parameter P808 for correct configuration

  3. 3

    Check voltage supply of the FSE24B module

  4. 4

    Check EtherCAT communication with the connected FSE24B for data exchange

Browse all codes in this manual (41)
Verified technical data. Last updated: April 2026

Related Faults

F01OvercurrentF03Ground faultF04Brake chopper
Source: SEW Eurodrive MOVITRAC 07B System
Open Manual (Page 353)Search more codes in this manual