F97

Copy error

SEW Eurodrive · MOVITRAC 07B System

What does F97 mean?

An immediate switch-off with inhibit occurs if the parameter module is removed during a copying process or if the unit is switched off/on while copying. This indicates an interruption during data transfer to or from the parameter module.

Common Causes

  • Parameter module removed during copying process
  • Switching off/on unit while copying is in progress

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Prior to fault acknowledgment, load factory settings or the complete data set from the parameter module to restore consistent data