Siemens · DCM
An exception, such as an invalid operation, division by zero, overflow, underflow, or imprecise result, occurred during a FloatingPoint data type operation. This error can originate from the base system or a specific application like FBLOCKS or DCC. The fault value (r0949) and r9999 provide detailed information about the cause and program counter at the time of the exception, indicating a critical calculation error.
Click steps to track your progress.
1. Perform a power cycle of the drive system (turn off, wait 30 seconds, turn on).
2. Back up parameters, then execute a factory reset (P0010 = 30, P0970 = 1) and carefully re-enter/restore configuration.
3. Review all parameters related to scaling, limits, and feedback (e.g., P0408 (Encoder pulses), P0076 (Analog input scaling)) for valid non-zero values where appropriate.
4. Update the drive's firmware to the latest stable version.
5. If the fault persists after all software and parameter checks, consider replacing the Control Unit due to potential hardware calculation unit failure.